Enquiries: 604-421-3108 | info@propanedepot.ca
Fisher 630 Series Commercial Direct-Operated High Pressure Regulators
Fisher 630 Series Commercial Direct-Operated High Pressure Regulator Specs
Fisher 630 Series Commercial Direct-Operated High Pressure Regulator Brochure
**To maximize the lifespan of the regulator, it must be installed above the liquid level of propane: directly connect to service valve, or wall mount above the propane cylinder(s).
630 Series Features/Specifications:
- High-Pressure Capabilities
- Rugged Construction
- Better Low-Pressure Control
- Sour Gas Service Capability
Body Size and End Connection Styles
- NPS 1 and 2 / DN 25 and 50 with an end connection of NPT, ASME CL150 RF, CL300 RF, or CL600 RF
- Maximum Inlet Pressure
- 1500 psig / 103 bar
- Maximum Outlet Pressure
- Up to 500 psig / 34.5 bar
- Outlet Pressure Range
- 3 to 500 psig / 0.21 to 34.5 bar in 10 ranges
- Pressure Registration
- Internal
- Temperature Capabilities
- Nitrile (NBR), Nylon (PA), and Neoprene (CR): -20 to 180°F / -29 to 82°C
Fluorocarbon (FKM) and Perfluoroelastomer (PTFE): 0 to 300°F / -18 to 149°C
- Approximate Weights
- 1-inch End Connection: 25 Pounds / 11.3 kg
2-inch End Connection: 30 Pounds / 13.6 kg
Fisher 627 Series Commercial Direct-Operated High Pressure Regulators
Fisher 627 Series Direct Operated High Pressure Regulators Specs
Fisher 627 Series Direct Operated High Pressure Regulators Brochure
**To maximize the lifespan of the regulator, it must be installed above the liquid level of propane: directly connect to service valve, or wall mount above the propane cylinder(s).
627 Series Features/Specifications:
- Internal Relief Valve
- Types 627R and 627MR Travel Stop
- Relief Operation Indicator
- Easy to Maintain
- Installation Adaptability
- Application Versatility
- Tamper-Resistant
- Wide Range of Flow Capabilities
Body Sizes and End Connection Styles
- 3/4, 1, or 2: NPT end connections
NPS 1 or 2 / DN 25 or 50: CL150 RF, CL300 RF, CL600 RF flanged end connections
- Maximum Inlet Pressure
- NPT Steel: 2000 psig / 138 bar
Flanged Steel: 1500 psig / 103 bar
Ductile Iron: 1000 psig / 69,0 bar
- Outlet Pressure Range
- 5 to 500 psig / 0,34 to 34,5 bar in six ranges
- Pressure Registration
- Type 627, 627H or 627R: Internal
Type 627M, 627HM or 627MR: External through 1/4 NPT internal control line connection in the diaphragm case
- Temperature Capabilities
- -20° to 180°F / -29° to 82°C
- Approximate Weights
- Ductile Iron or Steel Casings: 10 pounds / 5 kg
Aluminum Casings: 6.3 pounds / 3 kg
Rego 1580V Commercial Regulators
**To maximize the lifespan of the regulator, it must be installed above the liquid level of propane: directly connect to service valve, or wall mount above the propane cylinder(s).
Features/Specifications:
- Large nozzle and straight through flow provides high capacity and
resistance to freeze-up. - O-ring on retainer assembly provides a dampening effect to
reduce vibration. - Suitable for both liquid and vapor service.
- Can be readily fitted with pressure gauge in ¼” F. NPT port.
- Materials
Body ………………………………………………………….. Forged Aluminum
Bonnet …………………………………………………….. Die Cast Aluminum
Spring …………………………………………………………………………. Steel
Valve Seat Discs …………………………………………… Resilient Rubber
Diaphragms …………………. Integrated Fabric and Synthetic Rubber
Designed to reduce LP-Gas and anhydrous ammonia container pressures to between 3 and 125 PSIG. Precision-built with a multi-million BTU capacity, the 1580V series is perfect for such big, tough jobs as crop dryers, asphalt batch mixing plants, road building “tar wagons”, heat treating and other large industrial and commercial loads. It’s also ideal as a first stage regulator in large multiple operations. The AA1580V series is ideal for use in anhydrous ammonia applications such as blue print machines and heat treating.
Fisher Second Stage Regulators
Types R222, R622, R642, R652, and HSRL
Fisher Second Stage Regulators Specs
Fisher First, Second, 2PSI LP Gas Regulator Instruction Manual
**To maximize the lifespan of the regulator, it must be installed above the liquid level of propane: directly connect to service valve, or wall mount above the propane cylinder(s).
Types R222, R622, R642, R652, and HSRL Second-Stage regulators are Underwriters Laboratories (UL®) listed regulators designed to reduce the outlet pressure from a First-Stage regulator, usually 10 psig / 0.69 bar to 11 inches w.c. / 27 mbar, in domestic installations. Vents are screened with standard orientation over the inlet, but other orientations are available. Fisher® brand SecondStage regulators are painted palm green for easy identifi cation. Types R222, R622, R642, and R652 are equipped with a stainless steel inlet screen to reduce the mount of debris entering the regulator and have a temperature rating of -20 to 160ºF / -29 to 71ºC, but have passed Fisher internal testing for lockup, relief start to discharge and reseal down to -40ºF / -40ºC.
Fisher 67CH-742 High Pressure Regulator
- #1750
- 1.2Million BTU Capacity
- 30-60PSI range, PRESET at 40PSI
Fisher 67C Series is an Underwriters Laboratories (UL) listed high-pressure regulators
that meets a variety of applications in liquid or vapor service. The compact body design makes the 67C Series particularly useful in installations with space limitations.
The highly accurate 67CD Series eliminates the need for a pressure gauge on portable applications by using calibrated scales on the spring case, allowing visual adjustment of outlet pressure. The non-adjustable 67CN Series provides a tamper-resistant spring case and one of three fixed set points: 10, 15, or 20 psi / 0,69; 1,0; or 1,4 bar.
Fisher 67C Series carries an UL listing as a high pressure, non-relief regulator. This series contains brass materials that are not compatible with anhydrous ammonia service.
Our torch set up with this regulator includes:
– Connector to Torch Hose (135-LB) – Stock #1086
– 1.8GPM POL with XS Flow – Stock #3703
Marshall Excelsior MEGR350 Series High Pressure Regulators
**To maximize the lifespan of the regulator, it must be installed above the liquid level of propane: directly connect to service valve, or wall mount above the propane cylinder(s).
- MEGR350-10: 0-10 PSI adjustable – #3802
- MEGR350-20: 1.2Million BTU capacity, 0-20PSI adjustable – #3433
- MEGR350-30: 1.2Million BTU capacity, 0-30 PSI adjustable – #4698
The MEGR-350 is a single stage, adjustable high pressure regulator. The body and bonnet of both the fixed and adjustable regulators
are precisely machined and feature a crimped design and fabric reinforced rubber diaphragm creating a positive seal for leak-free
performance.
Features/Specifications:
- Type: Fixed / PSI
- Max. Inlet Pressure: 250 PSIG (17,2 bar)
- Inlet Connection: 1/4” FNPT
- Outlet Connections: 1/4” FNPT
- Orifice Diameter: 0.0625”
- Exterior Finish: Red Anodized
- Diaphragm: Fabric Reinforced Buna N
- Body/ Bonnet Material: Die Cast Zinc
- BTU/H Capacity: 1,200,000 BTU/H @ 40 PSI
- Listings: UL LISTED / UL 144
Marshall Excelsior MEGR130 Series High Pressure Regulators
**To maximize the lifespan of the regulator, it must be installed above the liquid level of propane: directly connect to service valve, or wall mount above the propane cylinder(s).
- MEGR130-10: Preset 10PSI outlet – #3683
- MEGR130-20: 600,000 BTU capacity – Preset 20PSI outlet – #3737
- MEGR130-30: 1.2Million BTU capacity – Preset 30PSI outlet – #3692
The MEGR-130 series fixed high pressure single stage regulators are designed to provide an economical solution for pounds to pounds service applications. The MEGR-130 can be used to regulate air as well as LP gas. Regulators must be installed in compliance with federal, state or local codes or laws in accordance with NFPA 58.
Features/Specifications:
- Type: Fixed / PSI
- Max. Inlet Pressure: 250 PSIG (17,2 bar)
- Inlet Connection: 1/4” FNPT
- Outlet Connections: 1/4” FNPT
- Orifice Diameter: 0.0625”
- Exterior Finish: Red Anodized
- Diaphragm: Fabric Reinforced Buna N
- Body/ Bonnet Material: Die Cast Zinc
- BTU/H Capacity: 1,200,000 BTU/H @ 40 PSI
- Listings: UL LISTED / UL 144
Fisher First Stage Regulators
- Type R122H
- Type R622H
Fisher First Stage Regulators Specs
Fisher R122H First Stage Regulator Brochure
Fisher R622H First Stage Regulator Brochure
Fisher First Stage Regulator Instruction Manual
**To maximize the lifespan of the regulator, it must be installed above the liquid level of propane: directly connect to service valve, or wall mount above the propane cylinder(s).
Features/Specifications:
- 20-Year Recommended Replacement Life
- Inlet/Outlet Gauge Taps for easy system checks
- Improved Regulation
- Easy Installation
- Superior Overpressure Protection
- Corrosion-Resistant
- Positive Draining Spring Case
- Durability
Propane Depot is closed on public holidays.
VANCOUVER LOCATION
Propane Filling/Cylinder Sales
Ph: 604-872-0800
1940 Main St
Vancouver, BC V5T 3B9
Mon-Fri: 8 am – 6 pm
Sat: 9 am – 6 pm
Sun: 10 am - 6 pm
BURNABY LOCATION
Showroom, Filling, Cylinder Sales
Ph: 604-421-3108
Toll-Free: 1-877-238-1279
3390 Lake City Way
Burnaby, BC V5A 3A6
Mon-Fri: 7 am - 6 pm
Sat: 9 am – 6 pm
Sun: 10 am – 6 pm
OUTSIDE SALES, RENTALS
LARGE PROJECTS
sales@propanedepot.ca
Ph: 236-998-0042
ACCOUNTING
Accounting: 604-564-0364
Receivables
receivables@propanedepot.ca
Payables
payables@propanedepot.ca