Unique UGP-6 6 cu/ft Propane Fridge
Certified for use in all provinces and states in North America.
*In Canada according to the 2010 Canada B149 Installation Code, if a propane fridge is being used in a dwelling it must be of the direct vent type. The direct vent propane fridge must be located/ installed on an outside wall (max. 18”/46cm distance). In all other applications, you can legally use propane fridges with either a CO alarming device with safety shut-off or direct vent system, based on your requirements. Please use a licensed gas fitter to install.
– Black: DV – #3380, CM – #3378
– White: DV – #3379, CM – #3377
Features:
- Battery Operated Interior Light
- Battery operated ignition
- Dual power allows for ‘brown’ applications/frequent power disruptions
- One large crisper drawer
- Adjustable glass shelves
- Doors Are Reversible
- Thermostat
- Front Mounted Controls
Operation: Propane/110V
Dimensions CO Monitor Model: (HxWxD)
Unboxed: 58 1/2″ x 23 1/2″ x 24 3/4″
Direct Vent Model (DV) Dimensions: (HxWxD)
Unboxed: 58 1/2″ x 23 1/2″ x 29″
Specifications
- Modern interior with glass shelves and a clear crisper
- Min. Clearances for Installation (from front): Left: 2” Top: 6” Right: 2” Back: 1”
- Gas Consumption: Approx. 1.1 lbs. LPG in 24 hr. period
- BTU: 1600 max., 700 min.
- AC Power: 110V, 2.5 AMP, 300 Watts
- Total: 6.4 cu/ft. / 181 Litres
- 4.9 cu/ft. / 139 Litres
- 1.5 cu/ft. / 42 Litres
Unique 6 Replacement Parts 2018
Unique UGP-8 8 cu/ft Propane Fridge
Certified for use in all provinces and states in North America.
*In Canada according to the 2010 Canada B149 Installation Code, if a propane fridge is being used in a dwelling it shall be of the direct vent type. The direct vent propane fridge must be located/ installed on an outside wall (max. 18”/46cm distance from outside wall). In all other applications in Canada, you can legally use propane fridges with either a CO alarming device with safety shut-off or direct vent system, based on your requirements. Please use a licensed gas fitter to install. *
– Black: DV – #3468, CM – #3467
– White: DV – #3215, CM – #3230
– Stainless: DV – #3167, CM – #3166
Features:
- Battery Operated Interior Light
- Battery operated ignition
- Dual power allows for ‘brown’ applications/frequent power disruptions
- One large crisper drawer
- Adjustable glass shelves
- Doors Are Reversible
- Thermostat
- Flame Indicator
- Front Mounted Controls
Specifications
- Modern interior with glass shelves and a clear crisper
- Dimensions (H x W x D): 64.5” x 23.5” x 25.25”
- Min. Clearances for Installation (from front): Left: 2” Top: 6” Right: 2” Back: 1”
- Gas Consumption: Approx. 1.1 lbs. LPG in 24 hr. period
- BTU: 1600 max., 700 min.
- AC Power: 110V, 2.5 AMP, 300 Watts
- Total: 8 cu/ft. / 227 Litres
- 6.3 cu/ft. / 179 Litres
- Freezer: 1.7 cu/ft. / 48 Litres
- Weight: 168 lbs/76 kg
Unique UGP-10 10 cu/ft Propane Fridge
Certified for use in all provinces and states in North America.
*In Canada according to the 2010 Canada B149 Installation Code, if a propane fridge is being used in a dwelling it shall be of the direct vent type. The direct vent propane fridge must be located/ installed on an outside wall (max. 18”/46cm distance from outside wall). In all other applications in Canada, you can legally use propane fridges with either a CO alarming device with safety shut-off or direct vent system, based on your requirements. Please use a licensed gas fitter to install. *
Features:
- Battery Operated Interior Light
- Battery operated ignition
- Dual power allows for ‘brown’ applications/frequent power disruptions
- One large crisper drawer
- Adjustable glass shelves
- Doors Are Reversible
- Thermostat
- Flame Indicator
- Front Mounted Controls
Dimensions CO Monitor Model: (HxWxD)
Unboxed: 64.5″ x 23.5″ x 28.25″
Direct Vent Model (DV) Dimensions: (HxWxD)
Unboxed: 65.5″ x 23.75″ x 33.25″
Specifications
- Modern interior with glass shelves and a clear crisper
- Min. Clearances for Installation (from front): Left: 2” Top: 6” Right: 2” Back: 1”
- Gas Consumption: Approx. 1.4 lbs. LPG in 24 hr. period
- BTU: 1600 max., 700 min.
- AC Power: 110V, 2.5 AMP, 300 Watts
- Total: 9.7 cu/ft. / 275 Litres
- Fridge: 7.6 cu/ft. / 215 Litres
- Freezer: 2.1 cu/ft. / 60 Litres
- Weight: 179 lbs/81 kg
Empire Gravity Wall Furnace – Chimney vented, no electricity needed - GWT 50
Empire GWT-50 Gravity Wall Furnace
Certified for use in all provinces and states in North America.
- No stock # – 50,000 BTU
Features:
- **Any units without blowers are off-grid
- **Any units with blowers require electricity to operate, including the optional blower kits
- State-of-the-Art Technology for Better Fuel Efficiency
- Thermostat not included
- Common Size Retrofits Easily
- GWT25W/35W Furnace Recesses into Wall or Mounts Flush with Optional GWTW2
- Total Comfort for a Fraction of the Cost of Electric Heat
- Optional Blower Available
- Made in USA
Specifications:
- W 16″ x D 6″ x H 66 1/8″
Height with blower kit: 71 7/8″
Shipping weight: 133lbs
Empire Gravity Wall Furnaces Brochure
Empire GWT-50 Gravity Wall Furnace Installation Manual 2018
Empire GWT-50 Replacement Parts
Empire Gravity Wall Furnace - Chimney vented, no electricity needed - GWT 25/35
Certified for use in all provinces and states in North America.
- GWT-25 – #4620 – 25,000 BTU
- GWT-35 – No stock # – 35,000 BTU
Features:
- **Any units without blowers are off-grid
- **Any units with blowers require electricity to operate, including the optional blower kits
- State-of-the-Art Technology for Better Fuel Efficiency
- Thermostat not included
- Common Size Retrofits Easily
- GWT25W/35W Furnace Recesses into Wall or Mounts Flush with Optional GWTW2
- Total Comfort for a Fraction of the Cost of Electric Heat
- Optional Blower Available
- Made in USA
Specifications:
- W 16″ x D 6″ x H 66 1/8″
Height with blower kit: 71 7/8″
Shipping weight: 86lbs
Empire Gravity Wall Furnaces Brochure
Direct Vent Empire Counterflow Wall Furnace - needs electricity - direct vent DVC models
Certified for use in all provinces and states in North America.
**All counterflow units have blowers included — electricity required — on-grid applications
- DVC55-SPPX – #1537 – Standing Pilot, Direct Vent (outside wall installation)
- DVC55-IPX – #4472 – Electronic Pilot, Direct Vent (outside wall installation)
- FAW55-SPPX – No Stock # – Standing Pilot, Vents through roof
- FAW55-IPX – #4471 – Electronic Pilot, Vents through roof
DVC55 and FAW55 Features:
- DVC55SPP/ DVC55IP (55,000 Btu) and DVC35SPP/DVC35IP (35,000) install on outside wall
- Thermostat not included
- Choose Standing Pilot or Electronic Intermittent Pilot (saves even more energy)
- Front Panels Remove for Cleaning and Servicing
- Counterflow Blower Circulates Warm Air at Floor Level
- Multi-Room Heating Capacity with Optional Outlet Kits
- Up to 76% A.F.U.E. efficient
- Made in USA
DVC55 and FAW55 Specifications:
- W 16″ x D 11 5/16″ x H 82 3/8″
Shipping weight: 140lbs (Two Boxes)
Empire Counterflow Vented and Direct Vent Wall Furnaces Brochure
Empire DV55 Counterflow Installation Manual 2018
Empire DVC55 Counterflow Replacement Parts
Empire FAW-55 Counterflow Installation Manual 2018
Empire FAW55 Counterflow Replacement Parts
Empire Counterflow Wall Furnaces - needs electricity - chimney vented FAW models
Certified for use in all provinces and states in North America.
**All counterflow units have blowers included — electricity required — on-grid applications
35,000BTU Units
- DVC35-SPPX – #4239 – Standing Pilot, Direct Vent (outside wall installation)
- DVC350IPX – #4783 – Electronic Pilot, Direct Vent (outside wall installation)
40,000 BTU Units
- FAW40-SPPX – #4489 – Standing Pilot, Vents through roof
- FAW40-IPX – No Stock # – Electronic Pilot, Vents through roof
DVC35 and FAW40 Features:
- DVC35-SPPX, DVC35-IPX (35,000 Btu) and FAW40-SPPX, FAW40-IPX recess between standard Wall Studs
- Thermostat not included
- Choose Standing Pilot or Electronic Intermittent Pilot (saves even more energy)
- Front Panels Remove for Cleaning and Servicing
- Counterflow Blower Circulates Warm Air at Floor Level
- Multi-Room Heating Capacity with Optional Outlet Kits
- Up to 76% A.F.U.E. efficient
- Made in USA
DVC35 and FAW40 Specifications:
- W 14 1/8″ x D10 3/8″ x H 72 1/2″
Shipping weight: 115lbs
Empire Counterflow Vented and Direct Vent Wall Furnaces Brochure
Empire DVC35 Counterflow Installation Manual 2018
Empire DVC35 Counterflow Replacement Parts
Empire FAW40 Counterflow Installation Manual 2018
Empire FAW40 Counterflow Replacement Parts
Empire RH-25 and RH-35 Vented Console Room Heaters - chimney vented
Certified for use in all provinces and states in North America.
- #4325
Features:
- **Vent piping not pictured, but heater must be vented
- Includes Thermostat
- Heats Without Electricity
- Optional Blower for On-Grid applications
- Matchless Piezo Ignition
- Made in USA
Specifications:
- RH-25 – 25,000BTUs
- RH-35 – 35,000BTUs
- Both RH-25 and RH-35 have the same dimensions:
W 37″x D 11 1/2″ x H 27 3/4″
Depth w/ diverter: 18 3/”
Shipping weight: 88lbs
Empire RH-25 – RH-65CB Visual Flame and Console Room Heaters Brochure
Empire RH-25 RH-35 Vented Console Manual 2018
Empire RH-25 RH-35 Vented Replacement Parts
Propane Depot is closed on public holidays.
VANCOUVER LOCATION
Propane Filling/Cylinder Sales
Ph: 604-872-0800
1940 Main St
Vancouver, BC V5T 3B9
Mon-Fri: 8 am – 6 pm
Sat: 9 am – 6 pm
Sun: 10 am - 6 pm
BURNABY LOCATION
Showroom, Filling, Cylinder Sales
Ph: 604-421-3108
Toll-Free: 1-877-238-1279
3390 Lake City Way
Burnaby, BC V5A 3A6
Mon-Fri: 7 am - 6 pm
Sat: 9 am – 6 pm
Sun: 10 am – 6 pm
OUTSIDE SALES, RENTALS
LARGE PROJECTS
sales@propanedepot.ca
Ph: 236-998-0042
ACCOUNTING
Accounting: 604-564-0364
Receivables
receivables@propanedepot.ca
Payables
payables@propanedepot.ca